:: SISTEMA PLEXOR HY ::
     
 
 
I
Ubicación
 
                   
 
CUANTIFICACION DE ADN » SISTEMA PLEXOR ® HY »
 
                 
 

Plexor ® HY System

   
 

The Plexor® HY System (a-g) is a real-time PCR assay specifically designed to determine the concentration of total human DNA and male human DNA simultaneously in one reaction. The kit contains an internal PCR control (IPC) to test for false-negative results that may occur in the presence of PCR inhibitors, and a melt curve function to confirm the correct product was amplified.

Plexor® HY is a sensitive multiplex kit, with routine detection of approximately 6.4pg total DNA. PCR amplification setup is performed at room temperature and is compatible with automated platforms.

The Plexor® Systems work by measuring a reduction in fluorescent signal during amplification. Amplification of each target uses only two primers, one of which contains both a fluorescent tag and a modified base. As amplification proceeds, fluorescence is reduced by site-specific incorporation of a fluorescent quencher inserted opposite the complementary modified base. The quencher is in close proximity to a fluorescent dye located on the end of the primer, resulting in a reduction in the fluorescent signal. After PCR, a melt analysis can be performed to provide an internal control for the final assay design or to expedite troubleshooting.

 

The Plexor® HY System is optimized for use on the Applied Biosystems 7500 and 7500 FAST real-time PCR systems and Stratagene Mx3005P® and Mx3000P® qPCR systems. For information about use with other qPCR instrumentation, contact Promega Technical Services.

The Plexor® Data Analysis Software is available for free download at: promega.com/plexorhy/ . The unique functions of this software allow you to quickly and easily review data and create reports. Replicate samples are automatically averaged, template amounts are calculated and the necessary volume of DNA is displayed for your optimized STR amplification conditions.

Schematic diagram illustrating the Plexor® real-time PCR process.

Plexor® HY autosomal PCR curves.

 

Features

Simultaneous Quantification of Autosomal and Y-Chromosome DNA: Less variability, less time, more valuable data.Consistent and Reproducible Detection of 6.4pg of DNA: If you can't detect it with Plexor® HY, you can't detect it with your STR system.

Internal Positive Control and Melt-Curve Analysis: Guard against false-negative and false-positive results, allowing you to be confident in your data.

 
Product
Size
Cat. No.
Plexor® HY System
800 reactions
DC1000
200 reactions
DC1001
Available Separately
Plexor® Calibration Kit, Set A
1 Each
DC1500
Water, Amplification Grade
6,250 µl (5x1,250µl)
DW0991
 
 
     
                 
 

DISTRIBUIDORA COMERCIAL ZOGBI
Municipio Libre No. 366 Col. Santa Cruz Atoyac C.P. 03310 Ciudad de México
Tels: 5601-3004 / 2856 / 2063
E-mail: jzogbi@dczogbi.com
cotizaciones@dczogbi.com